391 www.littelfuse.com 2ag fast-acting fuse 2206p series packaging options: 2206p series available on tape and reel per eia-296. 2206 series available in bulk packaging. for 1000 pieces bulk, add packaging suffix mxp. environmental specifications: operating temperature: ?5? to 125?. shock: mil-std-202, method 213, test condition i (100 g s peak for 6 milliseconds). vibration: mil-std-202, method 201 (10?5 hz, 0.06 inches total excursion). salt spray: mil-std-202 method 101, test condition b (48 hours). insulation resistance (after opening): mil-std-202, method 302, test condition b. resistance to soldering heat: (axial leaded fuses): mil-std-202, method 210a, test condition b (260?, 3 seconds). thermal shock: mil-std-202, method 107, test condition b (?5? to 125?). moisture resistance: mil-std-202, method 106 (90-98% rh, 65?). solderability: (axial leaded fuses): mil-std-202, method 208. physical specifications: materials: glass body, nickel-plated brass fuse caps. (insulating sleeve option available). soldering parameters: wave solder ?500? (260?), 3 seconds max. reflow solder ?not recommended. 2206 000p series 14.48 (.57") 4.7 (.184") 0.635 (.025") 38.1 (1.50") typ. axial lead material: tin coated copper. ordering information: axial lead nominal nominal catalog ampere voltage resistance melting i 2 t number rating rating cold ohms a 2 sec. 2206 .750p .750 300 0.340 2.95 2206 001p 1 300 0.210 5.64 2206 002p 2 300 0.0699 30.0 2206 003p 3 300 0.0505 50.0 subminiature glass body pb rohs physcialspecifications: materials: glass body, nickel-plated brass fuse caps soldering parameters: wave solder- 500?f(260?c), 3 seconds max. reflow solder- not recommended axial lead and cartridge fuses the 2ag fast-acting fuses are available with axial leads. axial leaded fuses are board washable. 2ag fuses provide the same performance characteristics as their 3ag counterpart, while occupying one-third the space. electrical characteristics: % of ampere opening rating time 100% 4 hours, min imum 135% 1 hour, max imum 200% 1 second, max imum agency approvals: all ratings are listed by ul and certified by csa. agency file numbers: ul e10480, csa lr 29862. interrupting ratings: 0.75?.0a 10,000 amperes at 125vac 0.75?.0a 35 amperes at 250vac
|